Multi-Sensor Monitoring System in Chemical Mechanical Planarization (CMP) for Correlations with Process Issues
H. Jeong, Pusan National University, Korea
H. Kim, G&P Technology, Busan, Korea
Sunghoon Lee, UC Berkeley
David Dornfeld, UC Berkeley
Jeong, H., Kim, H., Lee, S. and Dornfeld, D. (2006), “Multi-Sensor Monitoring System in Chemical Mechanical Planarization (CMP) for Correlations with Process Issues”, CIRP Annals, 55, 1, pp.
ABSTRACT: In this paper, three different sensors were used to measure multi-scale phenomena in chemical mechanical
planarization. A piezoelectric force sensor, Hall effect sensor and acoustic emission sensor (AE) were
installed in CMP equipment and the signals were measured simultaneously during the polishing process. The
results showed that the sensors measuring frictional behaviour, such as the Hall effect sensor and force
transducer, produced a clear end point signal in the case of the friction characteristics are distinguishable for
each material. Also, if there is difference in hardness between materials, then a sharp end point signal is
detected with the AE sensor even though the friction characteristic is similar between the two materials.
Therefore, using multi-sensors having different bandwidths is complementary for not only process monitoring
but also end point detection.
SUGGESTED CITATION: H. Jeong, H. Kim, Sunghoon Lee, and David Dornfeld,
"Multi-Sensor Monitoring System in Chemical Mechanical Planarization (CMP) for Correlations with Process Issues"
(January 1, 2006).
Laboratory for Manufacturing and Sustainability.
Precision Manufacturing Group.
Paper jeong_06_1.
http://repositories.cdlib.org/lma/pmg/jeong_06_1
|